{"id":259,"date":"2025-12-15T11:40:56","date_gmt":"2025-12-15T10:40:56","guid":{"rendered":"https:\/\/divi.zae.pl\/?page_id=259"},"modified":"2026-04-14T13:09:35","modified_gmt":"2026-04-14T11:09:35","slug":"rzr-as","status":"publish","type":"page","link":"https:\/\/divi.zae.pl\/index.php\/rzr-as\/","title":{"rendered":"RZR-AS"},"content":{"rendered":"\n<div class=\"et_pb_section_0 et_pb_section et_section_regular et_block_section preset--module--divi-section--default\"><div class=\"et_pb_row_0 et_pb_row et_block_row\"><div class=\"et_pb_column_0 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_heading_0 et_pb_heading et_pb_module et_block_module preset--module--divi-heading--a981e6ca-7fd8-45e6-9c38-41ce8df70846\"><div class=\"et_pb_heading_container\"><h1 class=\"et_pb_module_header\">RZR-AS<\/h1><\/div><\/div><\/div><\/div><div class=\"et_pb_row_1 et_pb_row et_block_row\"><div class=\"et_pb_column_1 et_pb_column et_pb_column_3_5 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><h4>Automatyka SZR<\/h4>\n<div id=\"c187\" class=\"csc-default\">\n<p class=\"bodytext\"><b>UWAGA! RZR-AS - zosta\u0142 wycofany z produkcji<\/b><\/p>\n<p class=\"bodytext\">Automat RZR\u00ae-AS jest mikroprocesorowym automatem do samoczynnego za\u0142\u0105czania napi\u0119cia rezerwowego (SZR) i automatycznego powrotu na zasilanie podstawowe (APZ) rozdzielni 0,4 kV. Gotowe do pracy urz\u0105dzenie zawiera wszystkie elementy pomocnicze tworz\u0105ce uk\u0142ad automatyki SZR-a: sterowanie wy\u0142\u0105cznikami lub stycznikami, przyciski steruj\u0105ce wy\u0142\u0105cznikami i agregatem, przyciski nawigacyjne do obs\u0142ugi i wprowadzania nastaw, wy\u015bwietlacz z wizualizacj\u0105 stanu uk\u0142adu, prze\u0142\u0105cznik trybu pracy i diody LED do sygnalizacji. Uzyskane w ten spos\u00f3b proste po\u0142\u0105czenia czterech element\u00f3w:<\/p>\n<ul>\n<li>automatu RZR\u00ae-AS,<\/li>\n<li>bezpiecznik\u00f3w w obwodach detekcji napi\u0119\u0107 zasilaj\u0105cych,<\/li>\n<li>element\u00f3w wykonawczych (wy\u0142\u0105czniki lub styczniki),<\/li>\n<li>zasilacza (dla uk\u0142ad\u00f3w z agregatem)<\/li>\n<\/ul>\n<p class=\"bodytext\">do minimum skraca czas monta\u017cu i uruchomienia rozdzielnicy SZR. Bezpo\u015brednie sterowanie element\u00f3w wykonawczych wybieranych w konfiguracji urz\u0105dzenia - wy\u0142\u0105cznik lub stycznik - eliminuje konieczno\u015b\u0107 stosowania przeka\u017anik\u00f3w pomocniczych<\/p>\n<\/div>\n<\/div><\/div><\/div><div class=\"et_pb_column_2 et_pb_column et_pb_column_2_5 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_module et_pb_button_module_wrapper et_pb_button_0_wrapper preset--module--divi-button--default_wrapper\"><a class=\"et_pb_button_0 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-button--default\" href=\"https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/RZR-Mikro_karta-2016_broszura.pdf\">Pobierz kart\u0119 katalogow\u0105<\/a><\/div><div class=\"et_pb_image_0 et_pb_image et_pb_module et_block_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/rzr-as.jpg\" width=\"600\" height=\"384\" srcset=\"https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/rzr-as.jpg 600w, https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/rzr-as-480x307.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 600px, 100vw\" class=\"wp-image-425\" title=\"rzr-as\" \/><\/span><\/div><\/div><\/div><div class=\"et_pb_row_2 et_pb_row et_block_row\"><div class=\"et_pb_column_3 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><div id=\"c188\" class=\"csc-default\">\n<div class=\"csc-header csc-header-n3\">\n<h4>Zastosowanie<\/h4>\n<\/div>\n<p class=\"bodytext\">Automat RZR\u00ae-AS zapewnia ci\u0105g\u0142o\u015b\u0107 zasilania w sieciach n\/n dla budynk\u00f3w u\u017cyteczno\u015bci publicznej, budynk\u00f3w mieszkalnych oraz obiekt\u00f3w przemys\u0142owych w uk\u0142adach: transformator - agregat lub dwa \u017ar\u00f3d\u0142a transformatorowe.<br \/>Automat realizuje:<\/p>\n<ul>\n<li>SZR - samoczynne za\u0142\u0105czenie rezerwy po zaniku napi\u0119cia,<\/li>\n<li>APZ - automatyczne prze\u0142\u0105czenie zasilania po powrocie napi\u0119cia (cykl powrotny),<\/li>\n<li>AZZ - automatyczne za\u0142\u0105czenie zasilania po w\u0142\u0105czeniu automatu do pracy,<\/li>\n<li>Start-Stop - generatora (zasilanie z UPS-a).<\/li>\n<\/ul>\n<\/div>\n<div id=\"c189\" class=\"csc-default\">\n<div class=\"csc-header csc-header-n4\">\n<h4>Cechy charakterystyczne<\/h4>\n<\/div>\n<ul>\n<li>Prostota i minimalizacja obszycia,<\/li>\n<li>Obudowa panelowa o ma\u0142ych wymiarach<\/li>\n<li>Uniwersalny monta\u017c \u2013 na drzwiach, na p\u0142ycie lub na szynie DIN,<\/li>\n<li>Wykonany przy wykorzystaniu nowoczesnego uk\u0142adu mikroprocesorowego typu RISC,<\/li>\n<li>Wygodna i prosta obs\u0142uga,<\/li>\n<li>Niski pob\u00f3r mocy,<\/li>\n<li>Du\u017ca odporno\u015b\u0107 na zak\u0142\u00f3cenia w obwodach wej\u015bciowych i wyj\u015bciowych,<\/li>\n<li>Bezpo\u015brednie sterowanie elementami komutacyjnymi (wy\u0142\u0105czniki, styczniki) \u2013 bez dodatkowego osprz\u0119tu,<\/li>\n<li>Sterowanie startem i zatrzymaniem agregatu.<\/li>\n<\/ul>\n<p class=\"bodytext\">Mo\u017cliwo\u015b\u0107:<br \/>- nastawiania parametr\u00f3w,<br \/>- zmiany konfiguracji pracy,<br \/>- monitorowania stanu rozdzielni (wy\u0142\u0105cznik\u00f3w i napi\u0119\u0107) na wy\u015bwietlaczu LCD i\u00a0 sygnalizacyjnych diodach LED,<br \/>- zewn\u0119trznej blokady automatu,<br \/>- wewn\u0119trznej blokady automatu ustawianej w konfiguracji dzia\u0142ania,<br \/>- ustawienia blokady trwa\u0142ej (wymaga kasowania przyciskami na panelu) i\u00a0chwilowej (zwalniana po zaniku sygna\u0142u zewn\u0119trznego),<br \/>- dodatkowe styki prze\u0142\u0105czne do sygnalizacji lub sterowania innymi urz\u0105dzeniami w trybie pracy zasilania z agregatu,<br \/>- dodatkowe wej\u015bcie sygnalizacyjne do integracji z zewn\u0119trznymi urz\u0105dzeniami (systemami).<\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_3 et_pb_row et_pb_equal_columns et_block_row\"><span class=\"et_pb_background_mask\"><\/span><div class=\"et_pb_column_4 et_pb_column et_pb_column_1_2 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><h2 style=\"text-align: center;\">Uproszczony schemat rozdzielni<\/h2>\n<\/div><\/div><\/div><div class=\"et_pb_column_5 et_pb_column et_pb_column_1_2 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_1 et_pb_image et_pb_module et_block_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/rzr-as_schemat.gif\" width=\"292\" height=\"255\" srcset=\"https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/rzr-as_schemat.gif 292w\" sizes=\"(max-width: 292px) 100vw, 292px\" class=\"wp-image-439\" title=\"rzr-as_schemat\" \/><\/span><\/div><\/div><\/div><div class=\"et_pb_row_4 et_pb_row et_pb_equal_columns et_block_row\"><div class=\"et_pb_column_6 et_pb_column et_pb_column_1_2 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_3 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><h4><strong>Dzia\u0142anie<\/strong><\/h4>\n<p>Mikroprocesorowy uk\u0142ad pomiarowo-steruj\u0105cy kontroluje obecno\u015b\u0107 wszystkich napi\u0119\u0107 oraz stan wszystkich wy\u0142\u0105cznik\u00f3w, a nast\u0119pnie w zale\u017cno\u015bci od nich dokonuje prze\u0142\u0105cze\u0144 zgodnych z tabel\u0105 stanu.<\/p>\n<div id=\"c191\" class=\"csc-default\">\n<div class=\"csc-textpic csc-textpic-center csc-textpic-above\">\n<div class=\"csc-textpic-imagewrap\">\n<div class=\"csc-textpic-center-outer\">\n<div class=\"csc-textpic-center-inner\">\n<div class=\"csc-textpic-image csc-textpic-last\"><\/div>\n<div class=\"csc-textpic-image csc-textpic-last\">Sterowanie wy\u0142\u0105cznikami odbywa si\u0119 za po\u015brednictwem dw\u00f3ch sygna\u0142\u00f3w steruj\u0105cych cewkami ka\u017cdego wy\u0142\u0105cznika: za\u0142\u0105czaj\u0105cym i wy\u0142\u0105czaj\u0105cym. Natomiast ich po\u0142o\u017cenie kontrolowane jest stanem styk\u00f3w pomocniczych. Jedynie ich jednoznaczny stan zezwala na prac\u0119 automatu.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"csc-textpic-text\">\n<p class=\"bodytext\">Automat mo\u017ce by\u0107 zasilany jednym z napi\u0119\u0107 wej\u015bciowych, wybieranym automatycznie przez zewn\u0119trzny uk\u0142ad prze\u0142\u0105czaj\u0105cy. Napi\u0119cie to r\u00f3wnie\u017c mo\u017ce s\u0142u\u017cy\u0107 do sterowania wy\u0142\u0105cznikami. Przy takim rozwi\u0105zaniu\u00a0 automat nie potrzebuje napi\u0119cia pomocniczego. Podczas pracy automatu z generatorem wymagane jest zasilenie urz\u0105dzenia z UPS-a.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"et_pb_column_7 et_pb_column et_pb_column_1_2 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_2 et_pb_image et_pb_module et_block_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/rzr-as_polaczenia.gif\" width=\"310\" height=\"157\" srcset=\"https:\/\/divi.zae.pl\/wp-content\/uploads\/2025\/12\/rzr-as_polaczenia.gif 310w\" sizes=\"(max-width: 310px) 100vw, 310px\" class=\"wp-image-440\" title=\"rzr-as_polaczenia\" \/><\/span><\/div><\/div><\/div><div class=\"et_pb_row_5 et_pb_row et_pb_equal_columns et_block_row\"><div class=\"et_pb_column_8 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_4 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><h4>Budowa<\/h4>\n<div id=\"c192\" class=\"csc-default\">\n<p class=\"bodytext\">Automat umieszczony jest w obudowie panelowej zgodnej z normami DIN 43700\/IEC 61554 8.4, przystosowanej do monta\u017cu zatablicowego oraz z mo\u017cliwo\u015bci\u0105 monta\u017cu na p\u0142ycie lub szynie DIN dzi\u0119ki dodatkowym uchwytom.<br \/>Na p\u0142ycie czo\u0142owej automatu znajduj\u0105 si\u0119:<\/p>\n<ul>\n<li>wy\u015bwietlacz LCD,<\/li>\n<li>sygnalizacja LED obecno\u015bci napi\u0119cia zasilaj\u0105cego automat,<\/li>\n<li>sygnalizacja LED zewn\u0119trznej blokady,<\/li>\n<li>sygnalizacja LED obecno\u015bci napi\u0119cia nadzorowanych tor\u00f3w zasilania rozdzielni ,<\/li>\n<li>sygnalizacja LED za\u0142\u0105czonej pozycji wy\u0142\u0105cznik\u00f3w (stycznik\u00f3w) ,<\/li>\n<li>sze\u015b\u0107 chwilowych przycisk\u00f3w s\u0142u\u017c\u0105cych do sterowania wy\u0142\u0105cznikami (stycznikami) i agregatem,<\/li>\n<li>cztery chwilowe przyciski nawigacyjne do obs\u0142ugi i zmiany ustawie\u0144 parametr\u00f3w dzia\u0142ania automatu,<\/li>\n<li>dwupozycyjny prze\u0142\u0105cznik trybu pracy z kluczykiem.<\/li>\n<\/ul>\n<p class=\"bodytext\">Na tylnej p\u0142ycie obudowy urz\u0105dzenia umieszczone s\u0105 \u0142\u0105cz\u00f3wki do pod\u0142\u0105czenia automatu ze sterowanymi elementami wykonawczymi, bezpiecznik\u00f3w obwod\u00f3w detekcji napi\u0119cia i zasilania automatu. Urz\u0105dzenie jest standardowo wyposa\u017cone w port komunikacyjny RS232.<\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_6 et_pb_row et_block_row\"><div class=\"et_pb_column_9 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_5 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><h4>Dane techniczne<\/h4>\n<\/div><\/div><div class=\"et_pb_text_6 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module preset--module--divi-text--default\"><div class=\"et_pb_text_inner\"><table cellpadding=\"1\" cellspacing=\"1\" width=\"550px\" border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" class=\"t_head\" valign=\"top\">\n<p class=\"bodytext\">Podstawowe dane techniczne<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Znamionowe napi\u0019\u0119cie pomiarowe tr\u00f3jfazowe Un<\/p>\n<\/td>\n<td class=\"jasny\" width=\"350\">\n<p class=\"bodytext\">AC 400V 50Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Znamionowe napi\u0119cie zasilania Uz<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">AC 230 V + 10%, - 20%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Napi\u0119cie kontrolowanych faz<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">180 V AC 10%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Zakres nastawienia czasu op\u00f3\u017anienia<\/p>\n<ul>\n<li>rozruchu od zaniku napi\u0119cia<\/li>\n<li>rozruchu od powrotu napi\u0119cia<\/li>\n<li>rozruchu wy\u0142\u0105czania\/za\u0142\u0105czania wy\u0142\u0105cznika Q1<\/li>\n<li>rozruchu wy\u0142\u0105czania\/za\u0142\u0105czania wy\u0142\u0105cznika Q2<\/li>\n<li>rozruchu generatora<\/li>\n<li>wy\u0142\u0105czania generatora<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">.<\/p>\n<ul>\n<li>(0,0 \u00f7 10,0) s co 0,1 s<\/li>\n<li>(0,0 \u00f7 10,0) s co 0,1 s<\/li>\n<li>(0,0 \u00f7 10,0) s co 0,1 s<\/li>\n<li>(0,0 \u00f7 250,0) s co 1 s<\/li>\n<li>(1 \u00f7 6000) s co 1 s<\/li>\n<li>(1 \u00f7 6000) s co 1 s<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Czas trwania impuls\u00f3w wyj\u015bciowych do sterowania wy\u0142\u0105cznik\u00f3w<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">0,5 s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Uchyb cz\u0142on\u00f3w czasowych<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">\u2264 1 %<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Klasa cz\u0142on\u00f3w czasowych ze wzgl\u0119du na rozrzut<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Uchyb dodatkowy od wp\u0142ywu zmian napi\u0119cia zasilaj\u0105cego i temperatury<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">\u00b1 1 %<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Zakres temperatury pracy<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">(-5 \u00f7 +55) \u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Dopuszczalna wilgotno\u015b\u0107 wzgl\u0119dna<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">90% (bez kondensacji)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Obci\u0105\u017calno\u015b\u0107 zestyk\u00f3w steruj\u0105cych wy\u0142\u0105cznikami lub stycznikami:<br \/>\u2022 maksymalny pr\u0105d za\u0142\u0105czania<br \/>\u2022 znamionowy pr\u0105d obci\u0105\u017cenia zestyku<br \/>\u2013 w kategorii AC1<br \/>\u2013 w kategorii DC1<br \/>\u2022 trwa\u0142a<br \/>\u2022 maksymalne napi\u0119cie zestyk\u00f3w AC\/DC<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">\u2022 16 A<\/p>\n<p>- 16 A przy 250 V AC<br \/>- 16 A \/ 24 V DC<br \/>\u2022 16 A<br \/>\u2022 250 V \/ 300 V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Obci\u0105\u017calno\u015b\u0107 zestyk\u00f3w dedykowanych dla generatora i sygnalizacyjnych:<br \/>\u2022 maksymalny pr\u0105d za\u0142\u0105czania<br \/>\u2022 znamionowy pr\u0105d obci\u0105\u017cenia zestyku<br \/>\u2013 w kategorii AC1<br \/>\u2013 w kategorii DC1<br \/>\u2022 trwa\u0142a<br \/>\u2022 maksymalne napi\u0119cie zestyk\u00f3w AC\/DC<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">\u2022 15 A<\/p>\n<p>- 6 A przy 250 V AC<br \/>- 6 A \/ 24 V DC<br \/>\u2022 6 A<br \/>\u2022 250 V \/ 300 V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Znamionowy pob\u00f3r mocy<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">\u2264 10 W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Trwa\u0142o\u015b\u0107 \u0142\u0105czeniowa przeka\u017anik\u00f3w wyj\u015bciowych<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">&gt; 0,6 x 10<sup>5<\/sup><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Wymiary<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">(288 x 144 x 100) mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"szary\">\n<p class=\"bodytext\">Waga<\/p>\n<\/td>\n<td class=\"szary\">\n<p class=\"bodytext\">ok 1,0 kg<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"jasny\">\n<p class=\"bodytext\">Stopie\u0144 ochrony<\/p>\n<\/td>\n<td class=\"jasny\">\n<p class=\"bodytext\">IP 40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" class=\"szary\" valign=\"top\">\n<p class=\"bodytext\">Wyr\u00f3b zgodny z wymaganiami dyrektyw: LVD (2006\/95\/EC), EMC (2004\/108\/EC) i CE.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-259","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/pages\/259","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/comments?post=259"}],"version-history":[{"count":14,"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/pages\/259\/revisions"}],"predecessor-version":[{"id":794,"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/pages\/259\/revisions\/794"}],"wp:attachment":[{"href":"https:\/\/divi.zae.pl\/index.php\/wp-json\/wp\/v2\/media?parent=259"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}